Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 291
Filter
1.
Medicina (B.Aires) ; 83(5): 753-761, dic. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1534879

ABSTRACT

Resumen Introducción : La mortalidad de la endocarditis infec ciosa (EI) en Argentina continúa siendo elevada. El obje tivo del trabajo fue describir las características clínicas e identificar factores asociados a mortalidad en pacientes con EI de válvula nativa. Métodos : Estudio de cohorte retrospectiva que inclu yó pacientes adultos con diagnóstico de EI de válvula nativa internados durante 2011-2021. Resultados : Se incluyeron 129 pacientes con una edad promedio de 66±17 años. El organismo responsa ble más frecuente (38.8%, n = 50) fue el Staphylococcus aureus (SA). El 63.6% presentó criterios de indicación quirúrgica. La mortalidad durante la internación fue del 22.5%. En el análisis multivariado que incluyó índice de comorbilidad Charlson, infección por SA y la presencia de criterios de indicación quirúrgica, se observó un OR ajustado de mortalidad de 1.32 (IC95% 1.10-1.57; p = 0.003), 2.75 (IC95% 1.11-6.8; p = 0.028) y 4.14 (IC95% 1.34-12; p = 0.013), respectivamente. En el análisis mul tivariado para mortalidad alejada que agregó el criterio quirúrgico y la realización de cirugía durante la inter nación, se observó un OR ajustado de 1.62 (IC95% 1.31- 2.00; p < 001), 0.77 (IC95% 0.31-1.93; p = 0.58), 7.49 (IC95% 2.07-27.07; p = 0.002) y 0.21 (IC95% 0.06-0.70; p = 0.01), respectivamente. Conclusiones : La mortalidad de la EI se asoció al grado de comorbilidad previa, a la forma de presenta ción y, en relación inversa, a la realización oportuna del tratamiento quirúrgico.


Abstract Introduction : Mortality of infective endocarditis (IE) in Argentina continues to be high. The aim objective was to describe the clinical characteristics and identify factors associated with in-hospital and long-term mortality in patients with native valve IE. Methods : Retrospective cohort study including adult patients with diagnosis of native valve IE, hospitalized during 2011-2021. Results : A total of 129 patients with a mean age of 66±17 years were included. The most frequent respon sible organism was Staphylococcus aureus (SA) (38.8%). Surgical indication criteria were present in 63.6% of the patients. Mortality during hospitalization was 22.5% .In the multivariate analysis that included Charlson comorbidity index, SA infection and the presence of surgical indication criteria, an adjusted OR of mor tality of 1.32 (95%CI 1.10-1.57; p = 0.003), 2.75 (95%CI 1.11-6.8; p = 0.028) and 4.14 (95%CI 1.34-12; p = 0.013), respectively, was observed. In the multivariate analysis for long term mortality, that added surgical indication criteria and the performance of surgery during hospitalization, an adjusted OR of 1.62 (CI95% 1.31-2.00; p<001), 0.77 (95%CI 0.31-1.93; p = 0.58), 7.49 (95%CI 2.07-27.07; p = 0.002) and 0.21 (95%CI 0.06-0.70; p = 0.01), respec tively, was observed. Conclusions : Mortality in IE was associated with the degree of previous comorbidity, with the presence of surgical indication criteria and, inversely, with the timely completion of surgical treatment.

2.
Rev. chil. cardiol ; 42(3)dic. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1529983

ABSTRACT

Antecedentes: El autoinjerto de válvula pulmonar (VP) u operación de Ross (OpR) tiene excelentes resultados a largo plazo. Es superior a otros tipos de reemplazo valvular en jóvenes adultos, aunque no el estándar de primera línea. Un tiempo quirúrgico prolongado o alta morbimortalidad son importantes preocupaciones. Objetivos: Establecer la morbimortalidad asociada a la OpR por un período >10 años, considerando el tiempo quirúrgico, tasa de reoperación y supervivencia global (SG). Métodos: Cohorte prospectiva (1996-2012), en seguimiento hasta agosto-2023. La SG fue estimada desde la OpR hasta la última consulta o deceso. Mediante regresión de Cox (Hazard Ratio, HR) se estimaron factores asociados a la SG. Resultados: La serie consta de 161 pacientes: 118 de etiología congénita (73.3%), 17 infecciosa (10.6%), 26 reumática (16.1%). La lesión fue estenótica en 79 (49.1%), insuficiencia en 40 (24.8%), mixta en 42 (26.1%). La OpR fue urgente en 11 (6.8%). The median time of ECC and the operation was 149 y 232 minutos, respectivamente. Veintisiete pacientes requirieron reoperación (16.8%). Con una mediana de 19.7 años (17.2-22.2), 23 pacientes fallecieron (14.3%): 1/23 asociado a OpR, 17/23 por causa cardiovascular y 5/23 por causas no cardiovasculares. La lesión mixta se asoció a mayor mortalidad (HR 3.07; IC 95% 1.11-8.47; p=.029). Conclusiones: La OpR es un procedimiento con baja morbimortalidad. La lesión mixta es un factor de riesgo independiente de mayor mortalidad. Sin embargo, la mediana de tiempo de CEC y quirúrgico es prolongado frente a otras técnicas de reemplazo valvular.


Background: Pulmonary valve (PV) autograftor reoperation or Ross surgery (RS), presents excellent long-term results. It is superior to other types of PV replacement in young adults, although it is not the first-line gold standard. A longer operative time or high morbidity and mortality rates are important concerns. Aim: To establish the morbidity and mortality associated with RS for >10 years, considering operative time, reoperation rate and overall survival (OS). Methods: Prospective cohort (1996-2012), with a follow-up until August/2023. The OS was estimated from RS to the last consultation/death. Factors associated to OS were estimated using Cox regression (Hazard Ratio, HR) Results: 161 patients were included: the etiology was congenital (118, 73%), infectious (17, 10.6%), and rheumatic (26,16.1%). The lesion was stenotic in 79 (49.1%), heart failure in 40 (24.8%), mixed in 42 (26.1%). RS was urgent in 11 (6.8%). Extracorporeal circulation (ECC) and operative times were 149 and 232 minutes, respectively. Twenty-seven patients required reoperation (16.8%). With a median follow up of 19.7 years (17.2-22.2), 23 patients died (14.3%): 1/23 associated with RS, 17/23 due to cardiovascular causes, and 5/23 due to non-cardiovascular causes. Mixed injury was associated with higher mortality (HR 3.07; 95% CI 1.11-8.47; p=.029). Conclusions: RS is a procedure with low morbidity and mortality. Mixed injury is an independent risk factor for increased mortality. However, the median ECC and operative times were higher compared to other valvular replacement techniques.

3.
Rev. argent. cardiol ; 91(4): 257-262, nov. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535503

ABSTRACT

RESUMEN La difusión del reemplazo valvular aórtico percutáneo (TAVI) en la estenosis aórtica (EAo) generó la creación de un Heart Team (HT), para elegir el mejor tratamiento. Existen pocos reportes sobre su utilidad. Objetivos: analizar los resultados del tratamiento de los pacientes con EAo evaluados por un HT durante 10 años Material y métodos: Inclusión consecutiva de todos los pacientes con EAo candidatos a TAVI entre enero del 2012 y julio del 2021 para seleccionar el mejor tratamiento, incluyendo además Cirugía de reemplazo valvular aórtico (CRVA) y Tratamiento médico conservador (TMC). Resultados: De 841 pacientes, se asignaron a TAVI 455 (53%), CRVA 213 (24%) y TMC 183 (23%). El porcentaje asignado a TAVI aumentó con el tiempo de 48 a 62% (p < 0,05). Los pacientes que fueron a TAVI, con respecto a los enviados a CRVA, eran mayores (86 ± 7 vs 83 ± 7 años), con mayor EUROSCORE II (6,2, IC95% 5,7-6,6 vs 5,6, IC95% 4,4-6,5) y más frágiles (1,62 ± 1 vs 0,91 ± 1), en todos los casos p <0,01. La sobrevida actuarial (IC 95%) a 1 y a 2 años fue, para TAVI 88% (84-91%) y 82% (77-86%), para CRVA 83% (76-88%) y 78% (70-84%) y para TMC 70% (60-87%) y 59% (48-68%) respectivamente (p <0,001). Conclusiones: Durante los primeros 10 años de establecido un Heart Team para la toma de decisiones en EAo, se asignaron a TAVI aproximadamente la mitad y el resto se asignó por mitades a cirugía u observación. La sobrevida de los pacientes intervenidos fue similar a 2 años y mayor que la de los no intervenidos.


ABSTRACT As transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) became widespread, the need for a Heart Team (HT) arose to choose the best treatment. There are few reports regarding its usefulness. Objectives: To analyze treatment outcomes in patients with AS evaluated by a HT for 10 years. Methods: Consecutive enrollment of all patients with AS who were candidates for TAVI between January 2012 and July 2021 to choose the best treatment, including surgical aortic valve replacement (SAVR) and conservative medical management (CMM). Results: Out of 841 patients, 455 were assigned to TAVI (53%), 213 to SAVR (24%), and 183 to CMM (23%). The percentage assigned to TAVI has increased from 48% to 62% over time (p <0.05). Patients who underwent TAVI versus those who underwent SAVR were older (86 ± 7 vs. 83 ± 7 years), had a higher EUROSCORE II (6.2, 95% CI 5.7-6.6 vs. 5.6; 95% CI 4.4-6.5) and were frailer (1.62 ± 1 vs. 0.91 ± 1), in all cases p <0.01. Actuarial survival (95% CI) at 1 and 2 years was 88% (84-91%) and 82% (77-86%) for TAVI, 83% (76-88%) and 78% (70-84%) for SAVR, and 70% (60-87%) and 59% (48-68%) for CMM, respectively (p <0.001). Conclusions: For the first 10 years after a Heart Team was established for AS decision-making, approximately half of the patients were assigned to TAVI, and the rest were equally assigned in halves to either surgery or observation. Survival for patients who received interventions was similar at 2 years and higher than in those who did not.

4.
Medisur ; 21(5)oct. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1521214

ABSTRACT

Se presenta el caso de una paciente de 35 años, femenina, con antecedentes de presentar un soplo desde la infancia y que debía ser intervenida quirúrgicamente por fibroma uterino. El anestesiólogo, durante la consulta preoperatoria, constató el soplo ya mencionado por lo que se decidió posponer la cirugía e interconsultar con un cardiólogo. El examen ecocardiográfico demostró que la paciente era portadora de una estenosis aórtica severa con fracción de eyección conservada, prueba ergométrica: clase funcional I, sin isquemia. Mediante anestesia general orotraqueal, se realizó histerectomía total abdominal sin complicaciones. Es de vital importancia para el anestesiólogo el manejo perioperatorio de la estenosis aórtica.


The case of a 35-years-old female patient with a history of presenting a murmur since childhood and who had to undergo surgery for uterine fibroid is presented. The anesthesiologist, during the preoperative consultation, verified the aforementioned murmur, so it was decided to postpone surgery and consult with a cardiologist. The echocardiographic examination showed that the patient had severe aortic stenosis with preserved ejection fraction, stress test: functional class I, without ischemia. Using orotracheal general anesthesia, a total abdominal hysterectomy was performed without complications. The perioperative management of aortic stenosis is of vital importance for the anesthesiologist.

5.
Arch. cardiol. Méx ; 93(3): 308-317, jul.-sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1513584

ABSTRACT

Abstract Background: Aortic valve (AV) replacement is the gold standard treatment for severe symptomatic AV disease. Recently, AV reconstruction surgery (Ozaki procedure) emerges as a surgical alternative with good results in the medium term. Methods: We retrospectively analyzed 37 patients who underwent AV reconstruction surgery between January 2018 and June 2020 in a national reference center in Lima, Peru. The median age was 62 years, interquartile range (IQR: 42-68). The main indication for surgery was AV stenosis (62.2%), in most cases due to bicuspid valve (19 patients, 51.4%). Twenty-two (59.4%) patients had another pathology with surgical indication associated to AV disease, 8 (21.6%) had dilatation of the ascending aorta with indication for replacement. Results: One in-hospital death occurred (1/38, 2.7%) due to perioperative myocardial infarction. There was a significant reduction in the medians of the peak (70 mmHg, CI 95% = 50.03-79.86 vs. 14 mmHg, CI 95% = 11.93-17.5, p < 0.0001) and mean (45.5 mmHg CI 95% = 30.6-49.68 vs. 7 mmHg, CI 95% = 5.93-9.6, p < 0.0001) AV gradients when we compared baseline characteristics with first 30-days results. In an average of 19 (± 8.9) months of follow-up, survival, reoperation-free survival for valve dysfunction, and survival free of AV insufficiency ≥ II were 97.3%, 100% and 91.9%, respectively. Significant reduction in the medians of the peak and mean AV gradients was maintained. Conclusions: AV reconstruction surgery showed optimal results in term of mortality, reoperation-free survival, and hemodynamic characteristics of the neo-AV.


Resumen Introducción: El reemplazo de la válvula aórtica es el tratamiento de elección para la valvulopatía aórtica severa sintomática. Recientemente, la cirugía de reconstrucción valvular aórtica (procedimiento de Ozaki) emerge como una alternativa quirúrgica con buenos resultados a mediano plazo. Métodos: Analizamos retrospectivamente 37 pacientes intervenidos de reconstrucción de válvula aórtica entre enero de 2018 y junio de 2020 en un centro de referencia nacional en Lima, Perú. La mediana de edad fue de 62 años (rango intercuartílico: 42-68). La estenosis de la válvula fue la principal indicación de cirugía (62.2%), en la mayoría de los casos por válvula bicúspide (19 pacientes, 51.4%). 22 (59.4%) pacientes presentaban otra patología con indicación de cirugía, 8 (21.6%) presentaban dilatación de la aorta ascendente con indicación de reemplazo. Resultados: La mortalidad intrahospitalaria fue de 1/38, 2.7%, por infarto de miocardio perioperatorio. Hubo una reducción significativa en las medianas del gradiente máximo (70 mmHg, IC 95% = 50.03-79.86 vs. 14 mmHg, IC 95% = 11.93-17.5, p < 0.0001) y gradiente medio (45.5 mmHg IC 95% = 30.6-49.68 vs. 7 mmHg, IC 95% = 5.93-9.6, p < 0.0001) de la válvula aórtica cuando comparamos las características basales con los resultados de los primeros 30 días. En una media de 19 (± 8.9) meses de seguimiento la sobrevida fue del 97.3%; la sobrevida libre de reoperación por disfunción valvular, 100% y la sobrevida libre de insuficiencia aórtica ≥ II, 91.9%, respectivamente. Se mantuvo una reducción significativa en las medianas de los gradientes máximo y medio de la válvula aórtica. Conclusiones: La cirugía de reconstrucción de válvula aórtica con pericardio autólogo mostró resultados óptimos en términos de mortalidad, supervivencia libre de reoperación y características hemodinámicas de la neo-válvula.

6.
Article in English | LILACS-Express | LILACS | ID: biblio-1535904

ABSTRACT

Introduction: The Deloyers procedure is a valuable technique used in reconstructing bowel transit following an extended left colectomy, a Hartmann-type colostomy, or repeated colon resections. It enables the creation of a tension-free colorectal or coloanal anastomosis. Case presentation: A 60-year-old female patient presented for consultation regarding the closure of a colostomy. Her medical history included segmental colectomy of the sigmoid and descending colon, resulting in a Hartmann-type colostomy due to complicated diverticulitis. The patient underwent laparoscopic surgery, during which a segment of the transverse colon with a short mesocolon was identified. Due to the complete release of the colon, a colorectal anastomosis could not be performed. As an alternative to preserving the ileocecal valve and achieving a tension-free colorectal anastomosis, the patient underwent the Deloyers procedure. Discussion: The Deloyers procedure involves tension-free anastomosis between the right colon and the rectum or anus. It includes complete mobilization and a 180° counterclockwise rotation of the hepatic angle and the right colon. The right and middle colic vessels are divided, while preserving the ileocolic pedicle and the ileocecal valve, thus avoiding the need for total colectomy and ileorectal anastomosis, which may yield unsatisfactory functional outcomes. Conclusion: The Deloyers procedure represents a viable alternative to ileorectal or ileoanal anastomosis, offering satisfactory functional outcomes.


Introducción: el procedimiento de Deloyers es una técnica útil en la reconstrucción del tránsito intestinal posterior a una colectomía izquierda ampliada, colostomía tipo Hartmann o resecciones colónicas iterativas, pues asegura una anastomosis colorrectal o coloanal sin tensión. Presentación del caso: una mujer de 60 años acudió a consulta para el cierre de una colostomía, con antecedente de colectomía segmentaria del sigmoides y colon descendente derivada con colostomía tipo Hartmann por diverticulitis complicada. Fue llevada a cirugía laparoscópica, en la que se encontró un segmento de colon transverso con meso corto y al liberarse completamente no se logró realizar la anastomosis colorrectal, por lo que se decidió realizar el procedimiento de Deloyers como alternativa para conservar la válvula ileocecal y obtener la anastomosis colorrectal libre de tensión. Discusión: el procedimiento de Deloyers consiste en la unión del colon derecho y recto o ano libre de tensión después de realizar la movilización completa y rotación de 180° en sentido antihorario del ángulo hepático y el colon derecho, en el que se seccionan los vasos cólicos derecho y medio, con preservación del pedículo ileocólico y la válvula ileocecal, para evitar la necesidad de una colectomía total y una anastomosis ileorrectal, para la cual los resultados funcionales pueden ser insatisfactorios. Conclusión: el procedimiento de Deloyers es una alternativa viable a la anastomosis ileorrectal o ileoanal con resultados funcionales satisfactorios.

7.
Rev. argent. cardiol ; 91(2): 125-137, jun. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1529590

ABSTRACT

RESUMEN Introducción : El reemplazo de la raíz aórtica con conservación valvular (valve-sparing aortic root replacement, VSAR) se ha consolidado como un procedimiento eficaz para el tratamiento del aneurisma de la raíz aórtica, el síndrome de Marfan, la válvula bicúspide y la disección aórtica. Sin embargo, es necesario llegar a una opinión unánime sobre los aspectos clave del VSAR. Material y métodos : Se realizó una revisión bibliográfica de los debates y controversias más frecuentes del VSAR. A partir de esta información se elaboró una encuesta en línea que se envió a cirujanos con experiencia comprobada en VSAR para conocer su opinión sobre los factores relacionados con los pacientes, los aspectos técnicos, la ecocardiografía, la investigación, la formación y el futuro del VSAR. Resultados : Veinte cirujanos completaron la encuesta. Según 14 de cada 20 encuestados, la fracción de eyección grave se consideró una contraindicación para el llevar a cabo este procedimiento. El límite del diámetro del anillo aórtico para la remodelación fue heterogéneo entre los participantes. Todos ellos consideraron que el VSAR es un procedimiento seguro para los pacientes con síndrome de Marfan y válvula bicúspide. En el caso de disección de tipo A, 11 de cada 20 prefirieron este procedimiento solo para los pacientes jóvenes. En lo que respecta al tamaño del injerto, la altura del triángulo intervalvar (8/20) y el diámetro sinotubular (7/20) fueron los más frecuentes. Los cirujanos informaron una tasa de fracaso del 7% en la conversión al procedimiento de Bentall, y un cambio de estrategia intraoperatoria del 26%. No se consideró que un abordaje mínimamente invasivo mejorara los resultados. La mayoría de los cirujanos coincidieron en que el VSAR lo deben realizar cirujanos con mucha experiencia. Conclusiones : El VSAR ha sido aceptado como una opción terapéutica para el aneurisma de la raíz aórtica, y, aunque todavía no es posible llegar a un consenso definitivo, se presenta la valiosa experiencia de los cirujanos más destacados en este campo.


ABSTRACT Background : The valve-sparing aortic root replacement (VSAR) has been established as a successful procedure for aortic root aneurysms, Marfan's syndrome, bicuspid valves, and aortic dissections. However, there is a need for a consensus opinion regarding key aspects of VSAR. Methods : A literature review was performed regarding the most frequent debates and controversies in VSAR. An online survey was developed based on this information, and sent to surgeons with known expertise in VSAR regarding their opinion on patient-related factors, technical aspects, echocardiography, research, training, and the future of VSAR. Results : Twenty surgeons completed the survey. The reduction of left ventricular ejection fraction was considered a contra indication to VSAR when severe by 14/20 surveyed. The aortic annulus diameter cutoff point for the remodeling was heterogenous among participants. All of them felt that VSAR is safe for the Marfan´s syndrome population and bicuspid valves. For type A dissections, 11/20 preferred this procedure only in young patients. Regarding to graft sizing, the height of the interleaflet triangle (8/20) and the sino-tubular diameter (7/20) were the more frequent considered parameters. Surgeons reported a 7% of failure rate, leading to conversion to Bentall surgery, and a 26% change of strategy intraoperatively. A minimally invasive approach was not considered to improve results. Most of the surgeons agreed that VSAR should be performed by high-experienced surgeons. Conclusions : The VSAR has been accepted as a treatment option for the aortic root´s aneurysms, and even though there is still not possible to reach a final consensus, a valuable experience from the most relevant surgeons in the field is presented.

8.
Medicina (B.Aires) ; 83(1): 126-128, abr. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1430781

ABSTRACT

Resumen Un varón de 49 años ingresó en la unidad de cuidados coronarios, con antecedentes de miocardiopatía dilatada, con función sistólica del ventrículo izquierdo gravemente deteriorada y estenosis aórtica grave de origen bicúspide, sintomático para síncope, ángor y disnea de reciente diagnóstico. Durante la internación evolucionó con shock cardiogénico que requirió doble soporte inotrópico. Por presentar alto riesgo quirúrgico y elevada probabilidad de rechazo ante un eventual trasplante cardiaco, según sus estudios de histocompatibilidad, se procedió al reemplazo transcatéter de la válvula aortica, con evolución favorable.


Abstract A 49-year-old male with a history of left ventricular systolic function dilated cardiomyopathy and severe symptomatic bicuspid aortic stenosis recently diagnosed (syncope, chest pain and dyspnea) was admitted to the coronary care unit. During hospitalization, he developed cardiogenic shock requiring double inotropic support. High surgical risk and an elevated chance of graft rejection contraindicated surgical replacement or heart transplant. We performed a transcatheter aortic valve replacement with a favorable evolution.

9.
Rev. argent. cardiol ; 91(1): 20-26, abr. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1529566

ABSTRACT

RESUMEN Objetivo : Analizar si la estrategia del implante alto usando superposición de las cúspides derechas e izquierdas (Cusp Overlap, COVL) en el implante percutáneo de la válvula aórtica (TAVI) se relaciona con menor incidencia de regurgitación paravalvular (RPV) moderada o grave, comparada con la estrategia convencional (CON). Material y métodos : Se analizaron 206 pacientes consecutivos que recibieron TAVI con válvulas autoexpandidles entre agosto de 2019 y mayo de 2022. Se utilizó una estrategia CON en 101 pacientes (49%) y COVL en 105 (51%). El Punto Final Primario (PFP) fue la presencia de regurgitación paravalvular moderada y grave a 30 días. Resultados : No hubo diferencia clínica entre los grupos en cuanto a la edad media, sexo ni comorbilidades; excepto una tendencia a más diabetes y angioplastia coronaria previa en el grupo COVL. El STS score fue mayor en el grupo de COVL (6,9 ± 2,2 vs. 5,8 ± 2,4 en CON, p = 0,01). A 30 días no hubo diferencia en el PFP (RPV moderada en 2% en CON, y 0,9% en COVL; ninguno presentó RPV grave). Tampoco hubo diferencia en mortalidad, infarto, oclusión coronaria, accidente cerebrovascular, sangrado mayor y complicación vascular. La necesidad de marcapasos definitivo fue menor con la estrategia de COVL (6,7% vs. 17,8%, p = 0,01) y un nuevo bloqueo de rama izquierda ocurrió en 5,7% vs. 12,9% (p = 0,07). Conclusiones : En esta serie de un solo centro, la estrategia del implante alto de la válvula aórtica percutánea usando la técnica de COVL no demostró diferencia en la presencia de regurgitaciones moderadas o graves comparada con la estrategia convencional, sin presentar diferencia en las complicaciones, y se asoció a una menor necesidad de marcapasos definitivo y a una tendencia de menos bloqueos de rama izquierda a 30 días.


ABSTRACT Objective : The aim of this study is to whether higher transcatheter aortic valve implantation (TAVI) with self-expandable valves using the right and left cusp overlap strategy (Cusp Overlap, COVL) is associated with a lower incidence of moderate or severe paravalvular regurgitation, compared with the conventional strategy (CON). Methods : A total of 206 consecutive patients undergoing TAVI with self-expandable valves between August 2019 and May 2022 were analyzed. The CON technique was used in the first 101 patients (49%) and COVL was used in 105 (51%). The primary endpoint (PEP) was the presence of moderate or severe paravalvular regurgitation at 30 days. Results : There were no clinical differences between the groups in terms of mean age, sex or comorbidities, except for a trend towards more patients with diabetes and previous percutaneous coronary intervention in the COVL group. The STS score was greater in the COVL group (6.9 ± 2.2 vs. 5.8 ± 2.4 in the CON group; p = 0.01). There was no difference in the PEP at 30 days with 2% incidence of moderate PVR in the CON group and 0.9% in the COVL group, and none of them presented severe PVR. There were no differences in mortality, myocardial infarction, coronary artery obstruction, stroke, major bleeding or vascular complications. The need for permanent pacemaker was lower with the COVL strategy (6.7% vs. 17.8%, p = 0.01) and a new left bundle branch block occurred in 5.7% vs. 12.9% (p = 0.07). Conclusions : In this single-center series, the strategy of high transcatheter aortic valve implantation using the COVL strategy showed no difference in the presence of moderate or severe regurgitation compared with the conventional strategy, with no differences in complications, and was associated with a lower need for definitive pacemaker and with a trend towards lower incidence of left bundle branch block at 30 days.

10.
Rev. argent. cardiol ; 91(1): 27-33, abr. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1529567

ABSTRACT

RESUMEN Introducción : La indicación de reemplazo valvular aórtico (RVA) en pacientes con estenosis aórtica (EA) grave asintomáticos con función conservada es motivo de creciente debate. Objetivos : Evaluar si la elevación de la fracción aminoterminal del pro-péptido natriurético tipo B (NT-proBNP) predice la aparición de síntomas y la indicación de reemplazo valvular en pacientes inicialmente asintomáticos, con EA grave y fracción de eyección ventricular izquierda (FEVI) conservada. Material y métodos : Se incluyeron en forma prospectiva pacientes con EA grave, FEVI conservada (≥55%) que fueron considerados asintomáticos, sin indicación inicial de RVA. A todos se les realizó laboratorio con medición de NT-proBNP en forma basal y ecocardiograma con Doppler tisular consignando la onda S de la pared lateral (S lat) y la relación E/e´. Se consideró como punto final el requerimiento de reemplazo valvular durante el seguimiento. Resultados : Se incluyeron 133 pacientes con una edad de 69 ± 8 años, 49% mujeres. Luego de un seguimiento de 570 (rango intercuartilo 380-680) días, el 23,3% (n = 31) de los pacientes presentaron requerimiento de reemplazo valvular. En el aná lisis multivariado, el NT-proBNP y la relación E/e´ fueron predictores independientes de requerimiento de cirugía (HR 1,02, IC95% 1,001-1,03, p <0,001; y HR 1,42, IC95% 1,21-2,45, p<0,001, respectivamente). El NT-proBNP presentó un Área Bajo la Curva (ABC) mayor que la relación E/e´ (0,88 versus 0,64, p = 0,02). Se estableció como mejor punto de corte de NT-proBNP un valor >350 pg./mL (HR ajustado 1,55, IC95% 1,38-2,01, p <0,001). Conclusiones : El NT-proBNP y la relación E/e´ fueron predictores independientes de requerimiento de cirugía. El NT-proBNP presentó una muy buena capacidad de discriminación, mayor que la relación E/e´.


ABSTRACT Background : The aortic valve replacement (AVR) indication in asymptomatic patients with severe aortic stenosis (AS) and preserved function is being increasingly discussed. Objective : The aim of this study was to evaluate whether the elevation of the N-terminal fraction of the pro-B-type natriuretic peptide (NT-proBNP) predicts the occurrence of symptoms and the AVR indication in patients with severe AS and preserved left ventricular ejection fraction (LVEF), initially asymptomatic. Methods : Asymptomatic patients with severe AS, preserved EF (≥55%) and no initial AVR indication were prospectively included. All patients underwent laboratory tests measuring NT-proBNP at baseline and an echocardiogram with tissue Doppler recording the lateral wall S wave (lat. S) and the E/e´ ratio. The endpoint was the aortic valve replacement indication at follow-up. Results : We included 133 patients aged 69 ± 8 years, 49% of which were women. After a follow-up of 570 (interquartile range 380-680) days, 23.3% (n=31) of them required aortic valve replacement. In the multivariate analysis, NT-proBNP value and the E/e´ ratio were 2 independent predictors of surgery (HR 1.02, 95% CI 1.001-1.03) p<0.001 and HR 1.42, 95% CI 1.21- 2.45, p< 0.001, respectively). NT-proBNP presented an area under the curve (AUC) greater than the E/e' ratio (0.88 versus 0.64, p=0.02). The best NT-proBNP cut-off point was determined >350 pg/mL (adjusted HR 1.55, 95% CI 1.38-2.01, p<0.001) Conclusion : NT-proBNP value and the E/e´ ratio were independent predictors of the AVR requirement. NT-proBNP had a very good discrimination capacity, greater than the E/e´ ratio.

11.
Acta méd. peru ; 40(1)ene. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1439122

ABSTRACT

Objetivo : Describir el seguimiento de los resultados de la cirugía de reemplazo valvular aórtico en un hospital de referencia nacional en Lima Perú, periodo 2016- 2019. Materiales y métodos : Se realizó un estudio retrospectivo de pacientes intervenidos quirúrgicamente de reemplazo valvular aórtico entre 2016 y 2019. Se determinaron las características pre, intra y postoperatorias, así como el seguimiento clínico y ecocardiográfico. Resultados : Se incluyeron 110 pacientes (59,1% varones), la edad media fue de 65,2 ± 11,3 años, la mayoría con hipertensión arterial (47,3%). La etiología más frecuente fue la degenerativa (47,3%). Se implantó prótesis mecánica en el 59,1%. En el postoperatorio se observó una mediana de tiempo de ventilación mecánica de 8 horas, con una estancia media en UCI de 5,8 ± 6,7 días. Las complicaciones más frecuentes fueron atelectasias (21,8%), fibrilación auricular (19,1%), síndrome de bajo gasto, neumonía y daño renal agudo (7,3% cada una). La mortalidad hospitalaria fue del 5,5% (shock cardiogénico como causa frecuente). Durante el seguimiento a un año el 41,2% de pacientes estaban asintomáticos y el 57,7% fueron clasificados como NYHA II, se encontró disfunción de la prótesis en el 13,3% (la mayoría por fuga paravalvular). Conclusiones : La cirugía de reemplazo valvular aórtico en nuestro medio implica una mejora en la calidad de vida con buenos resultados funcionales, tasa de complicaciones y morbimortalidad comparable con la literatura mundial.


Objective : To describe the follow-up of the results of aortic valve replacement surgery in a national reference hospital in Lima, Peru, period 2016-2019. Materials and methods : A retrospective study of patients who underwent aortic valve replacement surgery between 2016 and 2019 was carried out. Pre, intra, and postoperative characteristics were determined, as well as clinical and echocardiographic follow-up. Results :110 patients were included (59.1% male), the mean age was 65.2 ± 11.3 years, the majority with arterial hypertension (47.3%). The most frequent etiology was degenerative (47.3%). A mechanical prosthesis was implanted in 59.1%. In the postoperative period, a median mechanical ventilation time of 8 hours was observed, with an average stay in the ICU of 5.8 ± 6.7 days. The most frequent complications were atelectasis (21.8%), atrial fibrillation (19.1%), low output syndrome, pneumonia, and acute kidney injury (7.3% each). Hospital mortality was 5.5% (cardiogenic shock as the frequent cause). During follow-up at one year, 41.2% of the patients were asymptomatic and 57.7% were classified as NYHA II, prosthesis dysfunction was found in 13.3% (the majority due to paravalvular leak). Conclusions : Aortic valve replacement surgery in our setting implies an improvement in quality of life with good functional results, complication rate, and morbidity and mortality comparable with the world literature.

12.
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1520020

ABSTRACT

La sífilis es causada por Treponema pallidum, es reconocida por la variedad de sus manifestaciones clínicas; compromete el sistema nervioso, tegumentario y cardiovascular. Las alteraciones cardiovasculares ocurren en 70% de los casos con sífilis no tratada, el 71% de las aortitis sifilíticas desarrollan aneurismas aórticos y la complicación más frecuente es la insuficiencia aórtica. El tratamiento va dirigido a la enfermedad subyacente, con manejo antibiótico para la sífilis terciaria y las complicaciones tromboembólicas y si requiere reparación quirúrgica. Presentamos un caso poco frecuente de un paciente diagnosticado de infección por el virus de la inmunodeficiencia humana y complicaciones cardiovasculares típicas de la sífilis terciaria, que precisó tratamiento médico y quirúrgico, que fue exitoso. Destacamos la pericia clínica de los profesionales de nuestra institución para diagnosticar e identificar las complicaciones cardiovasculares de la sífilis terciaria.


Syphilis is caused by Treponema pallidum and is recognized by the variety of its clinical manifestations; it involves the nervous, integumentary and cardiovascular systems. Cardiovascular alterations occur in 70% of cases with untreated syphilis, 71% of syphilitic aortitis develop aortic aneurysms and the most frequent complication is aortic insufficiency. Treatment is directed at the underlying disease, with antibiotic treatment for tertiary syphilis and thromboembolic complications and if necessary surgical repair. We present a rare case of a patient diagnosed with human immunodeficiency virus infection and cardiovascular complications typical of tertiary syphilis, who required medical and surgical treatment, which was successful. We highlight the clinical experience of our institution's professionals in the diagnosis and identification of cardiovascular complications of tertiary syphilis.


A sífilis é causada pelo Treponema pallidum e é reconhecida pela variedade de suas manifestações clínicas; ela afeta os sistemas nervoso, tegumentar e cardiovascular. As alterações cardiovasculares ocorrem em 70% dos casos de sífilis não tratada, 71% dos casos de aortite sifilítica desenvolvem aneurismas aórticos e a complicação mais frequente é a insuficiência aórtica. O tratamento é direcionado para a doença subjacente, com tratamento antibiótico para sífilis terciária e complicações tromboembólicas e, se necessário, reparo cirúrgico. Apresentamos um caso raro de um paciente diagnosticado com infecção pelo vírus da imunodeficiência humana e complicações cardiovasculares típicas da sífilis terciária, que precisou de tratamento médico e cirúrgico, que foi bem-sucedido. Apresentamos um caso raro de um paciente com diagnóstico de infecção pelo vírus da imunodeficiência humana e complicações cardiovasculares típicas da sífilis terciária, que necessitou de tratamento médico e cirúrgico, o qual foi bem-sucedido. Destacamos a experiência clínica dos profissionais de nossa instituição no diagnóstico e na identificação das complicações cardiovasculares da sífilis terciária.


Subject(s)
Humans , Male , Adult , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Aneurysm/etiology , Aortic Valve Insufficiency/etiology , Penicillin G Benzathine/therapeutic use , Syphilis, Cardiovascular/complications , Syphilis, Cardiovascular/diagnosis , Syphilis, Cardiovascular/drug therapy
15.
Arq. bras. cardiol ; 120(7): e20220701, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1447308

ABSTRACT

Resumo Fundamento Ensaios clínicos randomizados (ECRs) e estudos observacionais compararam a eficácia e a segurança do implante valvar transcateter (TAVR) e da substituição cirúrgica da valva aórtica (SAVR) em pacientes com estenose aórtica grave. Objetivos Comparar TAVR e SAVR em pacientes com diferentes riscos cirúrgicos, características da população e diferentes válvulas protéticas transcateter. Métodos Uma overview das revisões sistemáticas (RSs) foi realizada seguindo um protocolo estruturado. Os resultados foram agrupados por risco cirúrgico, características da população e diferentes válvulas. Os ECRs foram reanalisados por meio de metanálises nas RSs, e os resultados foram resumidos por meio do método GRADE. O nível de significância estatística adotado foi de 5%. Resultados Em comparação com a SAVR, os pacientes com alto risco cirúrgico submetidos à TAVR tiveram um risco menor de ( odds ratio , intervalo de confiança de 95%, diferença absoluta de risco) fibrilação atrial (FA) (0,5, 0,29-0,86, -106/1000) e hemorragia com risco à vida (0,29, 0,2-0,42, -215/1000). Pacientes com risco cirúrgico intermediário apresentaram menor risco de FA (0,27, 0,23-0,33, -255/1.000), hemorragia com risco à vida (0,15, 0,12-0,19, -330/1.000) e insuficiência renal aguda (IRA) (0,4, 0,26-0,62, -21/1000). Pacientes com baixo risco cirúrgico tiveram menor risco de morte (0,58, 0,34-0,97, -16/1000), acidente vascular encefálico (AVE) (0,51, 0,28-0,94, -15/1000), FA (0,16, 0,12-0,2, -295/1000), hemorragia com risco à vida (0,17, 0,05-0,55, -76/1000) e IRA (0,27, 0,13-0,55, -21/1000) e tiveram maior risco de implante de marca-passo definitivo (IMD) (4,22, 1,27 -14.02, 141/1000). Os dispositivos de geração mais recente tiveram um risco menor de FA em comparação com as gerações mais antigas, e pacientes usuários de dispositivos expansíveis por balão não apresentaram riscos maiores de IMD. Conclusões Este artigo apresenta evidências de que pacientes com risco cirúrgico baixo, intermediário e alto apresentam melhores desfechos quando tratados com TAVR em comparação com a SAVR.


Abstract Background Randomized controlled trials (RCTs) and observational studies have compared the efficacy and safety of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis. Objectives Compare TAVR and SAVR in patients with different surgical risks, population characteristics, and different transcatheter prosthetic valves. Methods An overview of systematic reviews (SRs) was conducted following a structured protocol. Results were grouped by surgical risk, population characteristics, and different valves. RCTs in the SRs were reanalyzed through meta-analyses, and the results were summarized using the GRADE method. The adopted level of statistical significance was 5%. Results Compared to SAVR, patients with high surgical risk using TAVR had a lower risk of (odds ratio, 95% confidence interval, absolute risk difference) atrial fibrillation (AF) (0.5, 0.29-0.86, -106/1000) and life-threatening bleeding (0.29, 0.2-0.42, -215/1000). Patients with intermediate surgical risk had a lower risk of AF (0.27, 0.23-0.33, -255/1000), life-threatening bleeding (0.15, 0.12-0.19, -330/1000), and acute renal failure (ARF) (0.4, 0.26-0.62, -21/1000). Patients with low surgical risk had a lower risk of death (0.58, 0.34-0.97, -16/1000), stroke (0.51, 0.28-0.94, -15/1000), AF (0.16, 0.12-0.2, -295/1000), life-threatening bleeding (0.17, 0.05-0.55, -76/1000), and ARF (0.27, 0.13-0.55, -21/1000), and had a higher risk of permanent pacemaker implantation (PPI) (4.22, 1.27-14.02, 141/1000). Newer generation devices had a lower risk of AF than older generations, and patients using balloon-expandable devices did not experience higher risks of PPI. Conclusions This paper provides evidence that patients at low, intermediate, and high surgical risks have better outcomes when treated with TAVR compared with SAVR.

16.
Gac. méd. Méx ; 158(6): 380-386, nov.-dic. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1430367

ABSTRACT

Resumen Introducción: Las bioprótesis de válvulas cardiacas son el estándar de oro para el reemplazo quirúrgico de la válvula aórtica en pacientes seleccionados. Objetivo: Evaluar la seguridad y eficacia de la válvula cardiaca bioprotésica del Instituto Nacional de Cardiología (INC) en humanos. Métodos: Estudio unicéntrico que incluyó 341 pacientes que se sometieron a reemplazo valvular quirúrgico único de válvula aórtica con válvula INC. Resultados: Se realizaron 318 implantes de novo (93 %) y 23 como segunda cirugía (7 %); las puntuaciones STS fueron de 1.4 y 1.8 % y el seguimiento de 42 y 46 meses, respectivamente. No existieron diferencias en las complicaciones ni en la tasa de implantación de marcapasos. Ambos grupos mantuvieron una FEVI normal. Se observó mejoría global en la clase funcional con empeoramiento solo en dos pacientes del grupo de novo. La disfunción de la prótesis INC que ameritó reintervención quirúrgica se observó en ocho pacientes (4.65 %) del grupo de novo versus un paciente (7.69 %) con segunda cirugía. Conclusiones: La válvula cardiaca INC es eficaz y segura, se asocia a baja tasa de complicaciones y mejoría de la clase funcional durante el seguimiento a largo plazo. Se necesitan estudios prospectivos comparativos de esta válvula.


Abstract Introduction: Heart valve bioprostheses are the gold standard for aortic valve surgical replacement in selected patients. Objective: To evaluate the safety and efficacy of the of the National Institute of Cardiology (INC) bioprosthetic heart alve of the National Institute of Cardiology (INC) bioprosthetic heart valve in humans. Methods: Single-center study that ncluded 341 patients who underwent single surgical aortic valve replacement with INC heart valve. Results: 318 implants were performed de novo (93%) and 23 as redo surgery (7%); STS scores were 1.4 and 1.8%, and follow-up was for 42 and 46 months, respectively. There were no differences in clinical complications or pacemaker implantation rate. Both groups maintained a normal LVEF. Overall improvement in functional class was observed, with worsening only in two patients of the de novo group. INC prosthesis dysfunction requiring surgical reintervention was observed in eight patients (4.65%) of the de novo group vs. one patient in the redo group. Conclusions: The INC heart valve is efficacious and safe, and is associated with a The INC heart valve is efficacious and safe, and is associated with a low rate of complications and functional class improvement during long-term follow-up. Prospective, comparative studies of this valve are required.

17.
Cambios rev med ; 21(2): 861, 30 Diciembre 2022. ilus.
Article in Spanish | LILACS | ID: biblio-1415640

ABSTRACT

INTRODUCCIÓN. Las enfermedades valvulares cardíacas han sido un foco de estudio y de evolución continua, pues existen grupos de pacientes seleccionados en quienes el cambio valvular es parte de su terapéutica. En 1960 surgió el modelo de prótesis de válvula en forma de esfera enjaulada de Albert Starr y Lowell Edwards. El diseño fue perfeccionándose y es usado hasta la actualidad ya que muestra resultados clínicos aceptables. OBJETIVO. Describir el caso de un paciente portador, de uno de los primeros prototipos de prótesis valvular cardiaca metálica Starr-Edwards vigente y funcional por más de 40 años. CASO CLÍNICO. Paciente masculino con prótesis Starr-Edwards en posición aórtica, quien hasta la fecha lleva más de 40 años de uso, mantiene la clase funcional II de la New York Heart Association, realizando anticoagulación con Warfarina así como controles estrictos del índice internacional normalizado. DISCUSIÓN. Es primordial la evaluación y seguimiento de portadores de prótesis valvular para analizar anifestaciones clínicas (disnea) y hallazgos en los exámenes de laboratorio o de imagen (ecografía) para el control clínico y hemodinámica del paciente, con la intención de contemplar circunstancias que podrían determinar la nueva intervención valvular. CONCLUSIONES. Las válvulas metálicas, en particular las del tipo de prótesis de Starr-Edwards presentan alto riesgo trombótico por lo que es recomendable mantener anticoagulación plena evitando valores de índice internacional normalizado muy elevados que podrían crear escenarios de eventos hemorrágicos. Varios pacientes portadores de una de las prótesis más antiguas como es el modelo la prótesis Starr-Edwards, pueden llegar a tener una mejor supervivencia y resultados clínicos aceptables.


INTRODUCTION. Cardiac valve diseases have been a focus of study and continuous evolution, since there are selected groups of patients in whom valve replacement is part of their therapy. In 1960, the caged sphere valve prosthesis model of Albert Starr and Lowell Edwards was developed. The design was refined and is still used today because it shows acceptable clinical results. OBJECTIVE. To describe the case of a patient with one of the first prototypes of Starr- Edwards metallic heart valve prosthesis, which has been in use and functional for more than 40 years. CLINICAL CASE. Male patient with Starr-Edwards prosthesis in aortic position, who to date has been used for more than 40 years, maintains functional class II of the New York Heart Association, performing anticoagulation with Warfarin as well as strict controls of the international normalized index. DISCUSSION. The evaluation and follow-up of valve prosthesis carriers is essential to analyze clinical manifestations (dyspnea) and findings in laboratory or imaging tests (ultrasound) for the clinical and hemodynamic control of the patient, with the intention of contemplating circumstances that could determine the new valve intervention. CONCLUSIONS. Metallic valves, particularly those of the Starr-Edwards prosthesis type, present a high thrombotic risk and it is therefore advisable to maintain full anticoagulation, avoiding very high values of the international normalized index that could create scenarios of hemorrhagic events. Several patients carrying one of the older prostheses, such as the Starr-Edwards prosthesis model, may have better survival and acceptable clinical results.


Subject(s)
Humans , Male , Aged , Aortic Valve , Postoperative Complications , Reoperation , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Cardiac Surgical Procedures , Quality of Life , Rheumatic Heart Disease , Atrial Fibrillation , Thoracic Surgery , Survival Analysis , Ecuador , Endocarditis , Aortic Valve Disease , Mitral Valve Stenosis
18.
Rev. colomb. cardiol ; 29(supl.4): 1-4, dic. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1423803

ABSTRACT

Resumen Introducción: El síndrome de Lutembacher corresponde a la asociación de un defecto interauricular (congénito o iatrogénico) e insuficiencia o estenosis mitral (congénita o adquirida). La etiología reumática es la causa más frecuente del compromiso mitral. Tiene una prevalencia reportada de 0.001 por cada 1.000.000 habitantes. Caso clínico: Paciente femenina de 6 años con cuadro de 10 meses de palpitaciones asociadas a dolor torácico. Se realizó un electrogardiograma en el que se evidenció bloqueo incompleto de la rama derecha del haz de His y prolongación del intervalo PR, además de un ecocardiograma en el que se visualizó una comunicación interauricular tipo ostium secundum no restrictiva de 28 mm, con cortocircuito de izquierda a derecha, dilatación del ventrículo derecho, prolapso de válvula mitral, valvas engrosadas e insuficiencia mitral moderada a grave. Se realizó plastia de válvula mitral y cierre quirúrgico de la comunicación interauricular, sin complicaciones. Durante el seguimiento se encuentra asintomática desde el punto de vista cardiovascular, en manejo farmacológico. Conclusiones: La asociación Lutembacher tiene una prevalencia de 0.001/1.000.000 habitantes; la mayoría tiene etiología reumática. La paciente no tiene historia de fiebre reumática y sería la paciente más joven reportada en la literatura con síndrome de Lutembacher.


Abstract Introduction: Lutembacher’s syndrome corresponds to the association of an atrial septal defect (congenital or iatrogenic) and mitral regurgitation or stenosis (congenital or acquired), with rheumatic etiology being the most-frequent cause of mitral regurgitation. It has a reported prevalence of 0.001 for every 1,000,000 inhabitants. Clinical case: Female patient six years of age with a 10-month condition of palpitations associated with chest pain. An electrocardiogram was performed with evidence of incomplete right His bundle branch block and PR interval prolongation; additionally, an echocardiogram showed 28-mm non-restrictive ostium secundum atrial septal defect, with left-to-right shunt, right ventricular dilation, mitral valve prolapse, thickened valves, and moderate-to-severe mitral regurgitation. Mitral valve plasty and surgical closure of the atrial septal defect were performed, without complications. During follow-up, she was asymptomatic from the cardiovascular point of view, under pharmacological management. Conclusions: Lutembacher’s association has a prevalence of 0.001/1´000.000 inhabitants; the majority with rheumatic etiology. Our patient has no history of rheumatic fever and would be the youngest patient reported in the literature with Lutembacher’s syndrome.

19.
Rev. colomb. cardiol ; 29(supl.4): 38-41, dic. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1423810

ABSTRACT

Abstract We present the first case in Colombia of tricuspid endovascular valve in valve for failed bioprosthesis in a 40 years old patient with very high operative risk with great results, proposing kissing balloon annulus cracking technique as a practical solution for the colombian specialists.


Resumen Se presenta el primer caso en Colombia de un reemplazo percutáneo tipo válvula en válvula por falla de bioprótesis tricúspide en un paciente de 40 años con un muy alto riesgo quirúrgico, con excelentes resultados, proponiendo la técnica kissing balloon de fractura anular como una solución práctica para los especialistas colombianos.

SELECTION OF CITATIONS
SEARCH DETAIL